| Industrial Water Chiller
|
| Water Chiller
|
| Oil Chiller
|
| Low-Temp. Cold Air Jet
|
| Air Cooler for control box
|
| Swimming Pool Heat Pump
|
Air Source Heat Pump Water Heater
|
|
LFS Low Temperature Cold Air Jet |
|
|
 |
The temperature range of compressed air is from -10℃ to 60℃ |
 |
The temperature and flow of compressed air are tunable |
 |
Slender shape design, space saving |
| |
|
| |
Performance |
 |
Low temperature around the cutting point can stabilize the machining quality, and it is not necessary to compensate the machining size |
 |
There is no need for cooling fluid or oil, and the status can be observed directly. Also there is no harm to human body. |
 |
Low temperature around the cutting point can reduce the tool abrasion, greatly extend the tool use life and decrease the consumption of tool. |
 |
Reduce the machining preparing time and improve the processing efficiency. |
 |
The chips can be recycled directly without environmental pollution, and can help pass the ISO14000 authentication. |
 |
Eliminate work piece residual stress and improve processing accuracy |
 |
Low temperature around the cutting point ensures quality of machining of titanium, magnesium, molybdenum, stainless steel, hard-cutting and thin materials. |
| |
|
|
| Application Range |
 |
Grinder, lathe, miller and drilling machines |
| |
|
Low temperature cold air jet for single equipment with built-in drier
|
Item/Type |
LFS-085T30G |
LFS-180T30G |
LFS-085T60G |
LFS-180T60G |
Cooling medium |
Compressed air1 |
Application Range |
Ambient temperature |
5~35℃ |
Inlet temperature |
5~35℃ |
Inlet pressure |
0.4~0.95Mpa |
Processing flow2 |
Inlet flow |
0.85m3/min |
1.8m3/min |
0.85m3/min |
1.8m3/min |
Outlet flow |
0.74m3/min |
1.5m3/min |
0.74m3/min |
1.5m3/min |
Outlet temperature |
-10~-30℃ |
-40~-60℃ |
Power supply |
AC220V 50HZ |
Rated cooling capacity |
800W |
1100W |
3300W |
3600W |
Condenser cooling type |
Strong breeze cooling |
Cooling capacity control type |
Capillary |
Refrigerant |
R22 or R13 |
Refrigerant charge |
90Kg |
160Kg |
110Kg |
180Kg |
Dimensions(mm) |
420X670X915 |
485X925X1350 |
420X670X915 |
485X925X1350 |
|
| |
Low temperature cold air jet for concentrated process with external drier
|
Item/Type |
LFS-085T30 |
LFS-180T30 |
LFS-085T60 |
LFS-180T60 |
Cooling medium |
Compressed air, N2 3 |
Processing flow 2 |
Ambient air |
5~35℃ |
Inlet temperature |
5~35℃ |
Inlet pressure |
0.4~0.95Mpa |
Processing flow (注2) |
Inlet flow |
0.74m3/min |
1.5m3/min |
0.74m3/min |
1.5m3/min |
Outlet flow |
0.74m3/min |
1.5m3/min |
0.74m3/min |
1.5m3/min |
Outlet temperature |
-10~-30℃ |
-40~-60℃ |
Power supply |
AC220V 50HZ |
Rated cooling capacity |
800W |
1100W |
3300W |
3600W |
Condenser cooling type |
rong breeze cooling |
Cooling capacity control type |
Capillary |
Refrigerant |
R22 R13 |
Refrigerant charge |
90Kg |
160Kg |
110Kg |
180Kg |
Dimensions(mm) |
300X705X790 |
300X955X955 |
300X705X790 |
300X955X955 |
|
|
|
|
Note 1) |
The pressure dew point temperature is 10℃ before flow entering. |
Note 2) |
Above data are tested under the condition of entering water temperature 30℃, ambient temperature 30℃ and pressure 0.69Mpa. The outlet temperature varies with the change of inlet temperature and flow. |
Note 3) |
The flow must be filtered before connecting( the pressure dew temperature must be below -70℃). |
|
 |
|
|