Water Chiller for Machine Tool |
|
|
|
Prevent excursion of main machine spindle axis |
|
Prevent the deformation of main machine caused by heat expansion |
|
Extend tool life and improve the precision of machining size |
|
Precisely control machining fluid temperature, improve production efficiency and reduce cost |
|
Easy operation and low noise |
|
|
Rust free water circulation system |
|
Cooling water free |
|
Versatile control modes meet different requirements. |
Type Introduction |
LS |
- |
60 |
BX |
(G/T) |
a |
1 |
- |
2 |
3 |
4 |
5 |
|
|
1 |
LS single cooling type precision water chiller. LSR precision water chiller with heating function |
2 |
Rated cooling capacity=nominal rate×100, unit: w |
3 |
B with water pump;B2 with dual pump; BX with pump and tank |
4 |
(G) full-function control mode, factory setting is fixed temperature mode; (T): full-function control mode, factory-setting is tracing-temperature mode. |
5 |
Special order code |
|
| Application Range |
|
CNC liner cutter
|
|
High speed spindle
|
| |
PBC driller |
The electrode of welding machine and printing machine |
Semiconductor manufacturing and medical equipments |
Other places for water cooling |
| Main Technical Parameters |
|
|
Item/Type |
LS-15(B) |
LS-20(B) |
LS-25(B) |
LS-35(B) |
LS-50(B) |
LS-60(B) |
LS-70(B) |
With heating function |
LSR-15(B) |
LSR-20(B) |
LSR-25(B) |
LSR-35(B) |
LSR-50(B) |
LSR-60(B) |
LSR-70(B) |
Cooling capacity |
W |
1500 |
2000 |
2500 |
3500 |
5000 |
6000 |
7000 |
Kcal/H |
1290 |
1720 |
2150 |
3000 |
4300 |
5200 |
6000 |
Power supply |
3 phase 380V 50Hz(3 phase 5 line) |
3 phase 380V 50Hz(3phase 4line) |
Power input |
Compressor |
520 |
760 |
820 |
1205 |
1990 |
2580 |
3850 |
Fan motor |
85 |
85 |
85 |
85 |
230 |
230 |
320 |
Pump motor |
375 |
375 |
375(750) |
750(1500) |
1500 |
1500 |
1500 |
Flow (L/min.) |
10 |
10 |
10(16) |
16(25) |
32 |
32 |
32 |
Control range |
Fixed humidity type: 15-45oC; Tracing-temperature type: indoor temperature +T℃(T=0~±9) |
Range of use |
10~43℃ |
Cooling medium |
Clean water, water soluble fluid and other fluids without corrosion |
Dimensions (CM) |
37X45X86 |
37X45X86 |
40X50X92 |
48X53X100 |
53X60X106 |
53X60X106 |
53X60X106 |
|
| |
Item/Type |
LS-90(B) |
LS-100(B) |
LS-120(B) |
LS-150(B) |
LS-180(B) |
LS-240(B) |
LS-320(B) |
With heating function |
LSR-90(B) |
LSR-100(B) |
LSR-120(B) |
LSR-150(B) |
LSR-180(B) |
LSR-240(B) |
LSR-320(B) |
Cooling capacity |
W |
9000 |
10000 |
12000 |
15000 |
18000 |
24000 |
32000 |
Kcal/H |
7700 |
8600 |
10400 |
12900 |
15500 |
20600 |
27500 |
Power supply |
3 phase 380V 50Hz(3phase 4line)
|
Power input |
Compressor |
3000 |
3000 |
3500 |
3750 |
4500 |
6000 |
7500 |
Fan motor |
250 |
250 |
250 |
320 |
320 |
500 |
500 |
Pump motor |
2250 |
2250 |
2250 |
2250 |
2250 |
2250 |
2250 |
Flow (L/min.) |
50 |
50 |
50 |
50 |
85 |
85 |
100 |
Control range |
Fixed humidity type: 15-45oC; Tracing-temperature type: indoor temperature +T℃(T=0~±9) |
Range of use |
10~43℃ |
Cooling medium |
Clean water, water soluble fluid and other fluids without corrosion. |
Dimensions (CM) |
70X75X149 |
70X75X149 |
70X75X149 |
70X75X149 |
85X85X175 |
85X85X175 |
80X151X165 |
|
1. |
The cooling capacity test is based on the condition of ambient temperature 35℃ and entering water temperature 28℃. |
2. |
The sample is our standard product. Special order is also welcome. |
3. |
If used in cold regions, the heating function type product also can be offered. |
4. |
If a water tank is needed, please instruct the volume while order. |
5. |
Please keep the ventilation space of inlet and outlet more than 0.5m. Don’t block the ventilation space. |
6. |
Please install leakage circuit breaker in the power input terminal. |
7. |
Above parameters might change along with design changes without prior notice and the actural data are subject to the nameplate shown on the machine. |
|
|
|
|